Toyota Avalon (XX50) 2019-2022 Service & Repair Manual: Installation

INSTALLATION

CAUTION / NOTICE / HINT

NOTICE:

This procedure includes the installation of small-head bolts. Refer to Small-Head Bolts of Basic Repair Hint to identify the small-head bolts.

Click here

PROCEDURE

1. INSTALL WATER INLET WITH THERMOSTAT SUB-ASSEMBLY

(a) Install a new gasket to the water inlet with thermostat sub-assembly.

HINT:

Be sure to clean the contact surfaces.

(b) Using an 8 mm socket wrench, install the water inlet with thermostat sub-assembly with the 2 bolts.

Torque:

10 N·m {102 kgf·cm, 7 ft·lbf}

(c) Connect the No. 7 water by-pass hose to the water inlet with thermostat sub-assembly and slide the clip to secure it.

(d) Connect the water inlet with thermostat sub-assembly connector.

2. CONNECT NO. 2 RADIATOR HOSE

Click here

3. ADD ENGINE COOLANT (for Engine)

Click here

4. INSPECT FOR COOLANT LEAK (for Engine)

Click here

    Inspection

    Removal

    See More:

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Occupant Classification System(for Gasoline Model): System Diagram
    SYSTEM DIAGRAM Communication Table Transmitting ECU (Transmitter) Receiving ECU Signal Communication Method Airbag ECU Assembly Occupant Detection ECU Crash detection signal Acceleration signal CAN Skid Control ECU (Brake Actuator Assembly) Occupant Detection ECU Vehicle speed signal Occupant Detect ...