DESCRIPTION The cause of the malfunction may be a shutdown signal. Check whether there is a shutdown signal +B short circuit. Related Parts Check
SYSTEM DESCRIPTION Power supply to the motor is cut off due to a shutdown signal sent from the hybrid vehicle control ECU to the motor generator control ECU (MG ECU). WIRING DIAGRAM CAUTION / NOTICE / HINT This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs. If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC. CAUTION:
NOTICE: After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work. Click here PROCEDURE
(a) Turn the power switch on (IG).
(c) Turn the power switch off.
CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Disconnect the A42 inverter with converter assembly connector. (c) Disconnect the A24 hybrid vehicle control ECU connector. (d) Connect the cable to the negative (-) auxiliary battery terminal. (e) Turn the power switch on (IG).
(g) Turn the power switch off. (h) Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for 2 minutes or more. (i) Measure the resistance according to the value(s) in the table below. Standard Resistance:
(j) Reconnect the A24 hybrid vehicle control ECU connector. (k) Reconnect the A42 inverter with converter assembly connector.
CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Disconnect the A42 inverter with converter assembly connector.
(d) Reconnect the A42 inverter with converter assembly connector.
|
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Charging System: Problem Symptoms Table
PROBLEM SYMPTOMS TABLE HINT: Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected ...