Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
MIL | MIL status |
ON or OFF | OFF |
- |
Number of Emission DTC |
Emissions-related DTCs |
- | - |
- |
Complete Parts Monitor |
Comprehensive component monitor |
Not Avl or Avail | - |
- |
Fuel System Monitor |
Fuel system monitor | Not Avl or Avail |
- | - |
Misfire Monitor | Misfire monitor |
Not Avl or Avail | - |
- |
EGR/VVT Monitor |
EGR/VVT monitor | Not Avl or Avail |
- | - |
A/F (O2) Sensor Heater Monitor |
O2S (A/FS) heater monitor |
Not Avl or Avail | - |
- |
A/F (O2) Sensor Monitor |
O2S (A/FS) monitor | Not Avl or Avail |
- | - |
Secondary Air Injection System Monitor |
Secondary air injection system monitor |
Not Avl or Avail | - |
- |
EVAP Monitor |
EVAP monitor | Not Avl or Avail |
- | - |
Heated Catalyst Monitor |
Heated catalyst monitor |
Not Avl or Avail | - |
- |
Catalyst Monitor |
Catalyst monitor | Not Avl or Avail |
- | - |
EGR/VVT Monitor Result |
EGR/VVT monitor result |
Compl or Incmpl | - |
- |
A/F (O2) Sensor Heater Monitor Result |
A/F (O2) sensor heater monitor result |
Compl or Incmpl | - |
- |
A/F (O2) Sensor Monitor Result |
A/F (O2) sensor monitor result |
Compl or Incmpl | - |
- |
Secondary Air Injection System Monitor Result |
Secondary air injection system monitor result |
Compl or Incmpl | - |
- |
EVAP Monitor Result |
EVAP monitor result | Compl or Incmpl |
- | - |
Heated Catalyst Monitor Result |
Heated catalyst monitor result |
Compl or Incmpl | - |
- |
Catalyst Monitor Result |
Catalyst monitor result |
Compl or Incmpl | - |
- |
Calculate Load |
Calculate load (value increases in proportion to increase in load) |
Min.: 0.0%, Max.: 100.0% |
- | - |
Coolant Temperature | Engine coolant temperature |
Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Cold start→Fully warmed up: Gradually rises After warming up:
75 to 100°C (167 to 212°F) |
- |
Engine Speed |
Engine speed | Min.: 0 rpm, Max.: 16383 rpm |
950 to 1050 rpm: Idling |
- |
Vehicle Speed |
Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) |
Vehicle stopped: 0 km/h (0 mph) While driving at a constant speed:
No significant fluctuation |
- |
Intake Air Temperature |
Intake air temperature |
Min.: -40°C (-40°F), Max.: 140°C (284°F) |
Constant: Same as ambient air temperature |
- |
Throttle Position Sensor No.1 Voltage % |
Throttle position sensor |
Min.: 0.0%, Max.: 100.0% |
- | - |
OBD Requirements | OBD requirement |
- | - |
- |
Engine Run Time |
Elapsed time after starting engine |
Min.: 0 sec, Max.: 65535 sec |
- | Elapsed time from initial engine start until the power switch is turned off. |
MIL ON Run Distance | Drive distance from MIL on |
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
- | - |
Warmup Cycle Cleared DTC |
Warmup cycles after DTCs cleared |
Min.: 0, Max.: 255 | - |
- |
Distance from DTC Cleared |
Distance driven after DTCs cleared |
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
- | - |
Component Monitor Result (Current) |
Comprehensive component monitor (Current) |
Compl or Incmpl | - |
- |
Fuel System Monitor Result (Current) |
Fuel system monitor result (Current) |
Compl or Incmpl | - |
- |
Misfire Monitor Result (Current) |
Misfire monitor result (Current) |
Compl or Incmpl | - |
- |
Component Monitor ENA (Current) |
Comprehensive component monitor |
Unable or Enable | - |
- |
Fuel System Monitor ENA (Current) |
Fuel system monitor ENA (Current) |
Unable or Enable | - |
- |
Misfire Monitor ENA (Current) |
Misfire monitor ENA (Current) |
Unable or Enable | - |
- |
EGR/VVT Monitor ENA (Current) |
EGR/VVT monitor ENA (Current) |
Unable or Enable | - |
- |
O2 Sensor Heater ENA (Current) |
O2 sensor heater ENA (Current) |
Unable or Enable | - |
- |
A/F (O2) Sensor Monitor ENA (Current) |
A/F (O2) sensor monitor ENA (Current) |
Unable or Enable | - |
- |
Secondary Air Injection System Monitor ENA (Current) |
Secondary air injection system monitor ENA (Current) |
Unable or Enable | - |
- |
EVAP Monitor ENA (Current) |
EVAP monitor ENA (Current) |
Unable or Enable | - |
- |
Heated Catalyst Monitor ENA (Current) |
Heated catalyst monitor ENA (Current) |
Unable or Enable | - |
- |
Catalyst Monitor ENA (Current) |
Catalyst monitor ENA (Current) |
Unable or Enable | - |
- |
EGR/VVT Monitor Result (Current) |
EGR/VVT monitor result (Current) |
Compl or Incmpl | - |
- |
O2 Sensor Heater Monitor Result (Current) |
O2 sensor heater monitor result (Current) |
Compl or Incmpl | - |
- |
A/F (O2) Sensor Monitor Result (Current) |
A/F (O2) sensor monitor result (Current) |
Compl or Incmpl | - |
- |
Secondary Air Injection System Monitor Result (Current) |
Secondary air injection system monitor result (Current) |
Compl or Incmpl | - |
- |
EVAP Monitor Result (Current) |
EVAP monitor result (Current) |
Compl or Incmpl | - |
- |
Heated Catalyst Monitor Result (Current) |
Heated catalyst monitor result (Current) |
Compl or Incmpl | - |
- |
Catalyst Monitor Result (Current) |
Catalyst monitor result (Current) |
Compl or Incmpl | - |
- |
Battery Voltage |
Auxiliary battery voltage |
Min.: 0.00 V, Max.: 16.00 V |
11 to 15 V: Power switch on (IG) |
When
power switch on (READY): approx. 12.5 to 15.0 V. When power switch on
(IG): same as auxiliary battery voltage (approx. 12 V). If
the voltage becomes 11 V or less when the power switch is on (READY),
the hybrid vehicle control ECU stores inverter with converter assembly
DTCs. If the voltage becomes 9.5 V or less, the power switch will not be able to be turned on (READY). |
Ambient Temperature | Ambient air temperature |
Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Power switch on (IG): Same as ambient air temperature |
- |
Running Time from MIL ON |
Running time from MIL on |
Min.: 0 min, Max.: 65535 min |
- | - |
Time after DTC Cleared |
Time after DTCs cleared |
Min.: 0 min, Max.: 65535 min |
- | - |
Shift SW Status (N,P Range) |
Shift lever position sensor |
ON or OFF | Shift state P or N: ON
Shift state other than P or N: OFF |
- |
Hybrid/EV Battery System Voltage |
HV battery voltage | Min.: 0 V, Max.: 510 V |
Power switch on (READY): 150 to 300 V |
- |
Hybrid/EV Battery System Current |
HV battery current | Min.: -3276.8 A, Max.: 3276.7 A |
Power switch on (IG): -4 to 4 A |
- |
Boosting Converter Temperature(Upper) |
Boost converter temperature (Upper) |
Min.: 8°C (46.4°F), Max.: 150°C (302°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F) While driving with an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F) |
- |
Boosting Converter Temperature 1(Lower) |
Boost converter temperature 1 (Lower) |
Min.: 8°C (46.4°F), Max.: 150°C (302°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F) While driving with an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F) |
- |
Boosting Converter Temperature 2(Lower) |
Boost converter temperature 2 (Lower) |
Min.: 8°C (46.4°F), Max.: 150°C (302°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F) While driving with an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F) |
- |
Boosting Converter Temperature Duty(Upper) |
Boost converter temperature duty (Upper) (CPU input data) |
Min.: 0.0 %, Max.: 100.0 % |
- | - |
Motor Inverter Temperature Duty |
Motor inverter temperature duty (CPU input data) |
Min.: 0.0 %, Max.: 100.0 % |
- | - |
Motor Inverter Temperature |
Motor inverter temperature |
Min.: 8°C (46.4°F), Max.: 150°C (302°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F) While driving with an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F) |
- |
Motor U Current AD Value(Lower Resolution) |
Motor U phase current AD value (Lower resolution) |
Min.: 0.00 V, Max.: 4.99 V |
- | - |
Motor V Current AD Value(Lower Resolution) |
Motor V phase current AD value (Lower resolution) |
Min.: 0.00 V, Max.: 4.99 V |
- | - |
Motor W Current AD Value(Lower Resolution) |
Motor W phase current AD value (Lower resolution) |
Min.: 0.00 V, Max.: 4.99 V |
- | - |
Motor V Current AD Value(Higher Resolution) |
Motor V phase current AD value (Higher resolution) |
Min.: 0.00 V, Max.: 4.99 V |
- | - |
Motor W Current AD Value(Higher Resolution) |
Motor W phase current AD value (Higher resolution) |
Min.: 0.00 V, Max.: 4.99 V |
- | - |
Motor U Current(Lower Resolution) |
Motor U phase current (Lower resolution) |
Min.: -1000 A, Max.: 1000 A |
- | - |
Motor V Current(Lower Resolution) |
Motor V phase current (Lower resolution) |
Min.: -1000 A, Max.: 1000 A |
- | - |
Motor W Current(Lower Resolution) |
Motor W phase current (Lower resolution) |
Min.: -1000 A, Max.: 1000 A |
- | - |
Generator U Current(Lower Resolution) |
Generator U phase current (Lower resolution) |
Min.: -1000 A, Max.: 1000 A |
- | - |
Generator V Current(Lower Resolution) |
Generator V phase current (Lower resolution) |
Min.: -1000 A, Max.: 1000 A |
- | - |
Generator W Current(Lower Resolution) |
Generator W phase current (Lower resolution) |
Min.: -1000 A, Max.: 1000 A |
- | - |
Motor ECU Power Supply (For 31V) |
Motor generator control ECU power supply (for 31V) |
Min.: 0.00 V, Max.: 4.98 V |
- | - |
Motor ECU Power Supply (For AD0) |
Motor generator control ECU power supply (for AD0) |
Min.: 0.00 V, Max.: 4.98 V |
- | - |
Motor ECU Power Supply (For 2.5V) |
Motor generator control ECU power supply (for 2.5V) |
Min.: 0.00 V, Max.: 4.98 V |
- | - |
Motor ECU Power Supply (For 2.5V Sub) |
Motor generator control ECU power supply (for 2.5V sub) |
Min.: 0.00 V, Max.: 4.98 V |
- | - |
DC/DC Converter Operation State |
DC/DC converter status voltage |
Min.: 0.00 V, Max.: 4.98 V |
- | - |
DC/DC Converter Output Signal |
DC/DC converter output signal |
Min.: 0.00 V, Max.: 4.98 V |
- | - |
DC/DC Converter Output Signal Duty |
DC/DC converter output signal duty |
Min.: 0.0 %, Max.: 100.0 % |
- | - |
Motor Revolution | Motor (MG2) speed (detected by resolver sensor) |
Min.: -20000 rpm, Max.: 20000 rpm |
While driving: Varies depending on vehicle speed |
Motor (MG2) speed changes in proportion to vehicle speed. Motor (MG2) speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) speed. |
Motor Torque | Motor (MG2) torque value |
Min.: -500 Nm, Max.: 500 Nm |
While driving: Varies depending on vehicle operating conditions |
- |
Motor Control Mode |
Motor control mode | Min.: 0, Max.: 65535 |
- | - |
Motor Carrier Frequency |
Motor carrier frequency |
0.75 kHz, 1.25 kHz, 2.5 kHz, 3.75 kHz, 5 kHz, 10 kHz |
- | - |
Motor Inverter Shut Down Signal |
Motor inverter shutdown signal |
Min.: 0, Max.: 255 | - |
- |
Generator Revolution |
Generator (MG1) speed (detected by resolver sensor) |
Min.: -20000 rpm, Max.: 20000 rpm |
During charge or discharge: Varies depending on vehicle operating conditions |
Generator (MG1) speed is set to obtain requested target engine speed |
Generator Torque | Generator (MG1) torque value |
Min.: -500 Nm, Max.: 500 Nm |
During charge or discharge: Varies depending on vehicle operating conditions |
- |
Generator Control Mode |
Generator control mode |
Min.: 0, Max.: 65535 |
- | - |
Generator Carrier Frequency |
Generator carrier frequency |
0.75 kHz, 1.25 kHz, 2.5 kHz, 3.75 kHz, 5 kHz, 10 kHz |
- | - |
Generator Inverter Shut Down Signal |
Generator (MG1) inverter shutdown signal |
Min.: 0, Max.: 255 | - |
- |
Inverter Coolant Temperature AD Value |
Coolant (for inverter) temperature AD value |
Min.: 0.00 V, Max.: 4.99 V |
- | - |
Inverter Coolant Temperature |
Coolant (for inverter) temperature |
Min.: -40°C (-40°F), Max.: 110°C (230°F) |
Cold start→Fully warmed up: Gradually rises |
Normal: 64°C or less |
Inverter Input Current |
Inverter input current |
Min.: -1000 A, Max.: 1000 A |
- | - |
Inverter Water Pump Duty |
Inverter water pump motor driver request duty |
Min.: 0 %, Max.: 100 % |
Power switch on (READY): 40 to 85 % |
Hybrid vehicle control ECU |
Inverter Water Pump Revolution |
Inverter water pump assembly speed |
Min.: 0 rpm, Max.: 15000 rpm |
Power switch on (READY): 1051 to 8617 rpm |
When the inverter water pump assembly is not operating: 200 rpm or less |
Collinear Graphic Engine Revolution |
Col-linear graphic engine revolution |
Min.: 0 rpm, Max.: 65535 rpm |
- | - |
Motor Resolver After Offset |
Motor resolver after offset |
Min.: 0.000 deg, Max.: 358.593 deg |
- | - |
Motor Resolver Offset Value |
Motor resolver offset value |
Min.: -250.000 deg, Max.: 249.992 deg |
- | - |
Generator Resolver After Offset |
Generator resolver after offset |
Min.: 0.000 deg, Max.: 358.593 deg |
- | - |
Generator Resolver Offset Value |
Generator resolver offset value |
Min.: -250.000 deg, Max.: 249.992 deg |
- | - |
Motor Resolver Supply Voltage |
Motor resolver supply voltage |
Min.: 0.00 V, Max.: 4.99 V |
- | - |
VL Voltage | High voltage before it is boosted |
Min.: 0.0 V, Max.: 500.0 V |
Power switch on (READY): Practically the same as the HV battery voltage |
- |
VH Voltage |
High voltage after it is boosted |
Min.: 0.0 V, Max.: 1000.0 V |
Engine revving up with shift lever in P: After boosted voltage to below 650 V |
- |
Boosting Converter PWM Duty |
Boost converter PWM duty |
Min.: 0 %, Max.: 100 % |
- | - |
Boosting Converter Control Mode |
Boost converter control mode |
Min.: 0, Max.: 255 | - |
- |
Boosting Converter Carrier Frequency |
Boost converter signal carrier frequency |
9.55 kHz, 9.13 kHz, 8.71 kHz, 8.29 kHz, 7.87 kHz, 7.45 kHz, 4.8 kHz |
- | - |
Boosting Converter Shut Down Signal |
Boost converter shutdown signal |
Min.: 0, Max.: 255 | - |
- |
Generate Request Torque |
Generator (MG1) torque request value |
Min.: -4096.000 Nm, Max.: 4095.875 Nm |
- | - |
Shift Position | Shift position |
P / R / N / D / B | Matches currently selected shift state:
P, R, N or D | - |
Motor Temperature | Motor (MG2) temperature |
Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F) Changes according to vehicle condition and ambient temperature |
- |
Generator Temperature |
Generator (MG1) temperature |
Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F) Changes according to vehicle condition and ambient temperature |
- |
Short Wave Highest Value |
Waveform voltage in abnormal insulation detection circuit in battery voltage sensor |
Min.: 0.00 V, Max.: 4.98 V |
- | - |
Fail Safe Mode | Fail safe mode |
Min.: -128, Max.: 127 |
- | - |
Accelerator Position | Accelerator position |
Min.: 0 %, Max.: 100.0 % |
Accelerator pedal depressed: Changes with accelerator pedal pressure |
- |
WIN Control Limit Power |
Power flowing to HV battery (Charging) (detected at battery voltage sensor) |
Min.: -327.68 kW, Max.: 327.67 kW |
-38.76 kW or more | - |
WOUT Control Limit Power |
Power flowing from HV battery (Discharging) (detected at battery voltage sensor) |
Min.: -327.68 kW, Max.: 327.67 kW |
25.50 kW or less | - |
Engine Control Mode | Engine control mode |
Stop, Stop process, Startup process or Running |
- | - |
Emergency Shutdown Signal |
Inverter emergency shutdown |
ON or OFF | Inverter emergency shutdown:
ON Normal: OFF |
- |
Ready ON Status |
State of system (READY) |
ON or OFF | Power switch on (READY):
ON | - |
SMR Status | System main relay status |
ON or OFF | Power switch on (READY):
ON | - |
Generator Resolver Offset Complete Status |
Generator resolver learning complete status |
ON or OFF | Generator resolver learning has been completed:
ON | - |
Generator Inverter High Current(GFINV) |
Generator (MG1) inverter high current |
ON or OFF | Normal:
OFF | - |
Generator Inverter Shut Down Status |
Generator (MG1) inverter shutdown status |
ON or OFF | Generator inverter shutdown:
ON Normal: OFF |
- |
Motor Resolver Offset Complete Status |
Motor resolver learning complete status |
ON or OFF | Motor resolver learning has been completed:
ON | - |
PTC Heater Activate Permission Status/Prohibition Signal(IDH) |
PTC heater | ON or OFF |
- | - |
DC/DC Converter Terminate Signal |
DC/DC converter stop request signal |
ON or OFF | Normal:
OFF | - |
Motor Inverter High Current(MFINV) |
Motor inverter high current |
ON or OFF | Normal:
OFF | - |
Motor Inverter Shut Down Status |
Motor inverter shutdown |
ON or OFF | Motor inverter shutdown:
ON Normal: OFF |
- |
Inverter Input High Voltage(OVH) |
Inverter input high voltage |
ON or OFF | Normal:
OFF | - |
Boosting Converter Input High Voltage(OVL) |
Boost converter input high voltage |
ON or OFF | Normal:
OFF | - |
Boosting Converter Input High Current(CFINV) |
Boost converter input high current |
ON or OFF | Normal:
OFF | - |
Boosting Converter Shut Down Status |
Boost converter shutdown |
ON or OFF | Boost converter shutdown:
ON Normal: OFF |
- |
Total Distance Traveled |
Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) |
- | - |
Total Distance Traveled - Unit |
Drive total distance unit |
km or mile | - |
- |