Tester Display | Measurement Item |
Range | Diagnostic Note |
Calculate Load | Calculate load (value increases in proportion to increase in load) |
Min.: 0.0%, Max.: 100.0% |
- |
Coolant Temperature |
Engine coolant temperature |
Min.: -40°C (-40°F), Max.: 215°C (419°F) |
Cold or warmed-up engine |
Engine Speed | Engine speed |
Min.: 0 rpm, Max.: 16383 rpm |
- |
Vehicle Speed |
Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) |
Stopped, or driving (at low, medium, or high speeds) |
Intake Air Temperature |
Intake air temperature |
Min.: -40°C (-40°F), Max.: 140°C (284°F) |
- |
Throttle Position Sensor No.1 Voltage % |
Throttle position sensor |
Min.: 0.0%, Max.: 100.0% |
- |
Engine Run Time |
Elapsed time after starting engine |
Min.: 0 sec, Max.: 65535 sec |
After the power switch is turned on (READY), elapsed time from initial engine start until the power switch is turned off. |
MIL ON Run Distance | Drive distance from MIL on |
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
- |
Warmup Cycle Cleared DTC |
Warmup cycles after DTCs cleared |
Min.: 0, Max.: 255 | - |
Distance from DTC Cleared |
Distance driven after DTCs cleared |
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
- |
Battery Voltage |
Auxiliary battery voltage |
Min.: 0.00 V, Max.: 16.00 V |
Auxiliary battery and DC/DC converter condition |
Ambient Temperature | Ambient air temperature |
Min.: -40°C (-40°F), Max.: 215°C (419°F) |
- |
Running Time from MIL ON |
Running time from MIL on |
Min.: 0 min, Max.: 65535 min |
- |
Time after DTC Cleared |
Time after DTCs cleared |
Min.: 0 min, Max.: 65535 min |
- |
Shift SW Status (N,P Range) |
Shift lever position sensor |
ON or OFF | - |
Hybrid/EV Battery System Voltage |
HV battery voltage | Min.: 0.00 V, Max.: 1023.98 V |
- |
Hybrid/EV Battery System Current |
HV battery current | Min.: -3276.8 A, Max.: 3276.7 A |
HV battery charge/discharge status
- Amount of current during discharge is displayed with positive values
- Amount of current during charge is displayed with negative values
|
Boosting Converter Temperature(Upper) |
Boost converter temperature (Upper) |
Min.: 8°C (46.4°F), Max.: 150°C (302°F) |
- |
Boosting Converter Temperature 1(Lower) |
Boost converter temperature 1 (Lower) |
Min.: 8°C (46.4°F), Max.: 150°C (302°F) |
- |
Boosting Converter Temperature 2(Lower) |
Boost converter temperature 2 (Lower) |
Min.: 8°C (46.4°F), Max.: 150°C (302°F) |
- |
Motor Inverter Temperature |
Motor inverter temperature |
Min.: 8°C (46.4°F), Max.: 150°C (302°F) |
- |
Motor U Current(Lower Resolution) |
Motor U current (Lower resolution) |
Min.: -3276.8 A, Max.: 3276.7 A |
- |
Motor V Current(Lower Resolution) |
Motor V current (Lower resolution) |
Min.: -3276.8 A, Max.: 3276.7 A |
- |
Motor W Current(Lower Resolution) |
Motor W current (Lower resolution) |
Min.: -3276.8 A, Max.: 3276.7 A |
- |
Generator U Current(Lower Resolution) |
Generator U current (Lower resolution) |
Min.: -3276.8 A, Max.: 3276.7 A |
- |
Generator V Current(Lower Resolution) |
Generator V current (Lower resolution) |
Min.: -3276.8 A, Max.: 3276.7 A |
- |
Generator W Current(Lower Resolution) |
Generator W current (Lower resolution) |
Min.: -3276.8 A, Max.: 3276.7 A |
- |
Motor ECU Power Supply (For 31V) |
Motor generator control ECU power supply (for 31V) |
Min.: 0.00 V, Max.: 4.98 V |
- |
Motor ECU Power Supply (For AD0) |
Motor generator control ECU power supply (for AD0) |
Min.: 0.00 V, Max.: 4.98 V |
- |
Motor ECU Power Supply (For 2.5V) |
Motor generator control ECU power supply (for 2.5V) |
Min.: 0.00 V, Max.: 4.98 V |
- |
Motor ECU Power Supply (For 2.5V Sub) |
Motor generator control ECU power supply (for 2.5V sub) |
Min.: 0.00 V, Max.: 4.98 V |
- |
DC/DC Converter Operation State |
DC/DC converter operation state |
Min.: 0.00 V, Max.: 4.98 V |
- |
DC/DC Converter Output Signal |
DC/DC converter output signal |
Min.: 0.00 V, Max.: 4.98 V |
- |
DC/DC Converter Output Signal Duty |
DC/DC converter output signal duty |
Min.: 0.0 %, Max.: 100.0 % |
- |
Motor Revolution |
Motor (MG2) speed (detected by resolver sensor) |
Min.: -32768 rpm, Max.: 32767 rpm |
Motor (MG2) speed
- Forward rotation appears as "+"
- Backward rotation appears as "-"
|
Motor Torque |
Motor (MG2) torque value |
Min.: -4096.000 Nm, Max.: 4095.875 Nm |
When motor (MG2) rotates in "+" direction:
- Torque appears as "+" while motor (MG2) discharges
- Torque appears as "-" while motor (MG2) charges
When motor (MG2) rotates in "-" direction:
- Torque appears as "-" while motor (MG2) discharges
- Torque appears as "+" while motor (MG2) charges
|
Motor Control Mode |
Motor control mode | Min.: 0, Max.: 65535 |
- |
Motor Carrier Frequency |
Motor carrier frequency |
0.75 kHz, 1.25 kHz, 2.5 kHz, 3.75 kHz, 5 kHz, 10 kHz |
- |
Motor Inverter Shut Down Signal |
Motor inverter shutdown signal |
Min.: 0, Max.: 255 | - |
Generator Revolution | Generator (MG1) speed (detected by resolver sensor) |
Min.: -32768 rpm, Max.: 32767 rpm |
Generator (MG1) speed
- Forward rotation appears as "+"
- Backward rotation appears as "-"
|
Generator Torque |
Generator (MG1) torque value |
Min.: -4096.000 Nm, Max.: 4095.875 Nm |
When generator (MG1) rotates in "+" direction:
- Torque appears as "+" while generator (MG1) discharges
- Torque appears as "-" while generator (MG1) charges
When generator (MG1) rotates in "-" direction:
- Torque appears as "-" while generator (MG1) discharges
- Torque appears as "+" while generator (MG1) charges
|
Generator Control Mode |
Generator control mode |
Min.: 0, Max.: 65535 |
- |
Generator Carrier Frequency |
Generator carrier frequency |
0.75 kHz, 1.25 kHz, 2.5 kHz, 3.75 kHz, 5 kHz, 10 kHz |
- |
Generator Inverter Shut Down Signal |
Generator (MG1) inverter shutdown signal |
Min.: 0, Max.: 255 | - |
Inverter Coolant Temperature |
Coolant (for inverter) temperature |
Min.: -40°C (-40°F), Max.: 215°C (419°F) |
- |
Inverter Input Current |
Inverter input current |
Min.: -3276.8 A, Max.: 3276.7 A |
- |
Inverter Water Pump Duty |
Inverter water pump motor driver request duty |
Min.: 0 %, Max.: 100 % |
- |
Inverter Water Pump Revolution |
Inverter water pump assembly speed |
Min.: 0 rpm, Max.: 15000 rpm |
- |
Collinear Graphic Engine Revolution |
Col-linear graphic engine revolution |
Min.: 0 rpm, Max.: 65535 rpm |
- |
Motor Resolver After Offset |
Motor resolver offset value |
Min.: 0.000 deg, Max.: 358.593 deg |
- |
Motor Resolver Offset Value |
Motor Resolver Offset Value |
Min.: -250.000 deg, Max.: 249.992 deg |
- |
Generator Resolver After Offset |
Generator resolver offset value |
Min.: 0.000 deg, Max.: 358.593 deg |
- |
Generator Resolver Offset Value |
Generator resolver offset value |
Min.: -250.000 deg, Max.: 249.992 deg |
- |
VL Voltage |
High voltage before it is boosted |
Min.: 0.0 V, Max.: 6553.5 V |
- |
VH Voltage |
High voltage after it is boosted |
Min.: 0.0 V, Max.: 6553.5 V |
- |
Boosting Converter PWM Duty |
Boost converter PWM duty |
Min.: 0 %, Max.: 100 % |
- |
Boosting Converter Control Mode |
Boost converter control mode |
Min.: 0, Max.: 255 | - |
Boosting Converter Carrier Frequency |
Boost converter signal carrier frequency |
9.55 kHz, 9.13 kHz, 8.71 kHz, 8.29 kHz, 7.87 kHz, 7.45 kHz, 4.8 kHz |
- |
Boosting Converter Shut Down Signal |
Boost converter shutdown signal |
Min.: 0, Max.: 255 | - |
Generate Request Torque |
Generator (MG1) torque request value |
Min.: -4096.000 Nm, Max.: 4095.875 Nm |
- |
Shift Position |
Shift position | P/R/N/D |
- |
Motor Temperature |
Motor (MG2) temperature |
Min.: -40°C (-40°F), Max.: 215°C (419°F) |
- |
Generator Temperature |
Generator (MG1) temperature |
Min.: -40°C (-40°F), Max.: 215°C (419°F) |
- |
Short Wave Highest Value |
Waveform voltage in abnormal insulation detection circuit in battery voltage sensor |
Min.: 0.00 V, Max.: 4.98 V |
- |
Fail Safe Mode |
Fail safe mode | Min.: -128, Max.: 127 |
- |
Accelerator Position |
Accelerator pedal opening angle |
Min.: 0 %, Max.: 100.0 % |
- |
WIN Control Limit Power |
Charge control wattage sent from battery voltage sensor to hybrid vehicle control ECU |
Min.: -327.68 kW, Max.: 327.67 kW |
- |
WOUT Control Limit Power |
Discharge control wattage sent from battery voltage sensor to hybrid vehicle control ECU |
Min.: -327.68 kW, Max.: 327.67 kW |
- |
Engine Control Mode |
Engine control mode | Stop, Stop Process, Startup Process, Running |
- |
Emergency Shutdown Signal |
Inverter emergency shutdown |
ON or OFF | - |
Ready ON Status | State of system (READY) |
ON or OFF | - |
SMR Status | SMR status |
ON or OFF | - |
Generator Resolver Offset Complete Status |
Generator resolver learning complete status |
ON or OFF | - |
Generator Inverter High Current(GFINV) |
Generator (MG1) inverter high current |
ON or OFF | - |
Generator Inverter Shut Down Status |
Generator (MG1) inverter shutdown status |
ON or OFF | - |
Motor Resolver Offset Complete Status |
Motor resolver learning complete status |
ON or OFF | - |
PTC Heater Activate Permission Status/Prohibition Signal(IDH) |
PTC heater | ON or OFF |
- |
DC/DC Converter Terminate Signal |
DC/DC converter stop request signal |
ON or OFF | - |
Motor Inverter High Current(MFINV) |
Motor inverter high current |
ON or OFF | - |
Motor Inverter Shut Down Status |
Motor inverter shutdown |
ON or OFF | - |
Inverter Input High Voltage(OVH) |
Inverter input high voltage |
ON or OFF | - |
Boosting Converter Input High Voltage(OVL) |
Boost converter input high voltage |
ON or OFF | - |
Boosting Converter Input High Current(CFINV) |
Boost converter input high current |
ON or OFF | - |
Boosting Converter Shut Down Status |
Boost converter shutdown |
ON or OFF | - |
Total Distance Traveled |
Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) |
- |
Total Distance Traveled - Unit |
Drive total distance unit |
km or mile | - |