DESCRIPTION The inverter
with converter assembly monitors its internal operation and will store
this DTC if it detects a malfunction of its EEPROM.
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Warning Indicate |
P062F44 | Internal Control Module EEPROM Data Memory Failure |
ECU internal malfunction (EEPROM error) (1 trip detection logic) |
Inverter with converter assembly |
Comes on | Master Warning Light:
Does not come on | MONITOR DESCRIPTION
The
motor generator control ECU monitors its internal operation. If the
internal operation is malfunctioning, the motor generator control ECU
illuminates the MIL and stores a DTC. MONITOR STRATEGY
Related DTCs | P062F (INF P062F44): Internal Control Module EEPROM (Drive Motor "A" Control Module) |
Required sensors/components | Motor generator control ECU |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | 1 driving cycle |
Sequence of operation | None | TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property | Other conditions belong to TMC's intellectual property |
- | TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- | COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P062F (INF P062F44) is not detected | CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the
vehicle has returned to normal by performing the following All Readiness
check procedure.
Click here
- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 15 seconds or more. [*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
PROCEDURE
1. | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Click here
NEXT |
| COMPLETED | |