CAUTION / NOTICE / HINT HINT:
PROCEDURE
HINT:
(a) Measure the auxiliary battery voltage with the power switch off. Standard Voltage: 11 to 14 V If the voltage is below 11 V, recharge or replace the auxiliary battery before proceeding to the next step. (b) Check the fuses and relays. (c) Check the connector connections and terminals to make sure that there are no abnormalities such as loose connections, deformation, etc.
(a) Using the Techstream, check for CAN communication system DTCs. Click here
(a) Refer to Problem Symptoms Table. Click here
(a) Operation Check Click here (b) Terminals of ECU Click here (c) Data List / Active Test Click here (d) Inspection
|
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Hybrid Control System: Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range (P0A9B1C,P0AC51C,P0ACA1C)
DESCRIPTION These DTCs will be stored if the difference between the maximum and minimum output of each battery temperature sensors exceeds a certain amount and if the output of one battery temperature sensor deviates from that of the other sensors. DTC No. Detection Item DTC Detection Condition Trou ...