DIAGNOSIS SYSTEM CHECK DLC3 (a) Check the DLC3. Click here INSPECT AUXILIARY BATTERY VOLTAGE (a) Measure the auxiliary battery voltage with the power switch off. Standard Voltage: 11 to 14 V If the voltage is below 11 V, recharge or replace the auxiliary battery. |
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Hybrid Control System: High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction (P1C8349)
DTC SUMMARY MALFUNCTION DESCRIPTION The hybrid vehicle control ECU monitors the high-voltage wiring between the HV battery and inverter with converter assembly and detects a power supply malfunction. The cause of this malfunction may be one of the following: Inverter voltage sensor (VH) internal cir ...