Toyota Avalon (XX50) 2019-2022 Service & Repair Manual: Diagnosis System

DIAGNOSIS SYSTEM

CHECK DLC3

(a) Check the DLC3.

Click here

INSPECT AUXILIARY BATTERY VOLTAGE

(a) Measure the auxiliary battery voltage with the power switch off.

Standard Voltage:

11 to 14 V

If the voltage is below 11 V, recharge or replace the auxiliary battery.

    Data List / Active Test

    How To Proceed With Troubleshooting

    See More:

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Hybrid Control System: High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction (P1C8349)
    DTC SUMMARY MALFUNCTION DESCRIPTION The hybrid vehicle control ECU monitors the high-voltage wiring between the HV battery and inverter with converter assembly and detects a power supply malfunction. The cause of this malfunction may be one of the following: Inverter voltage sensor (VH) internal cir ...