Toyota Avalon (XX50) 2019-2022 Service & Repair Manual: Inspection

INSPECTION

PROCEDURE

1. INSPECT THERMISTOR ASSEMBLY

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

10°C (50°F)

3.00 to 3.73 kΩ

15°C (59°F)

2.45 to 2.88 kΩ

20°C (68°F)

1.95 to 2.30 kΩ

25°C (77°F)

1.60 to 1.80 kΩ

30°C (86°F)

1.28 to 1.47 kΩ

35°C (95°F)

1.00 to 1.22 kΩ

40°C (104°F)

0.80 to 1.00 kΩ

45°C (113°F)

0.65 to 0.85 kΩ

50°C (122°F)

0.50 to 0.70 kΩ

55°C (131°F)

0.44 to 0.60 kΩ

60°C (140°F)

0.36 to 0.50 kΩ

NOTICE:

  • Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
  • When measuring, the sensor temperature must be the same as the ambient temperature.

HINT:

As the temperature increases, the resistance decreases (see the graph).

If the result is not as specified, replace the thermistor assembly.

*a

Component without harness connected

(Thermistor Assembly)

*b

Sensing Portion

*c

Resistance (kΩ)

*d

Temperature (°C (°F))

*e

Allowable Range

    Components

    Installation

    See More:

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Power Window Control System(for Hv Model): Diagnostic Trouble Code Chart
    DIAGNOSTIC TROUBLE CODE CHART Power Window Control System (for HV Model) DTC No. Detection Item Link B2311 Power Window Motor Malfunction B2311 Power Window Motor Malfunction B2311 Power Window Motor Malfunction B2311 Power Window Motor Malfunction B2312 Power Window Switch Malfunction B2312 Power W ...

    Toyota Avalon (XX50) 2019-2022 Owners Manual

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual

    © 2025 Copyright www.tavalon.net
    0.0092