INSTALLATION PROCEDURE 1. INSTALL BLOWER ASSEMBLY (a) Engage the 2 guides and 2 claws. (b) Install the blower assembly to the air conditioning radiator assembly with the 2 screws. (c) Engage each guide. (d) Connect the connector. 2. INSTALL NO. 2 AIR DUCT Click here 3. INSTALL NO. 2 INSTRUMENT PANEL WIRE (w/ PTC Heater) Click here 4. INSTALL AIR CONDITIONER UNIT ASSEMBLY for A25A-FXS: Click here for 2GR-FKS: Click here |
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Trip Switch: Inspection
INSPECTION PROCEDURE 1. INSPECT TRIP SWITCH (a) Measure the resistance according to the value(s) in the table below. Standard Resistance: Tester Connection Condition Specified Condition 4 (RV) - 1 (E) Light control rheostat up switch pressed Below 50 Ω Light control rheostat up switch not pressed 1 ...