Toyota Avalon (XX50) 2019-2022 Service & Repair Manual: Inspection

INSPECTION

PROCEDURE

1. INSPECT NO. 1 COOLER THERMISTOR

(a) Measure the resistance according to the value(s) in the table below.

*a

Component without harness connected

(No. 1 Cooler Thermistor)

*b

Sensing Portion

*c

Resistance (kΩ)

*d

Temperature (°C (°F))

*e

Allowable Range

-

-

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

-10°C (14°F)

7.30 to 9.10 kΩ

-5°C (23°F)

5.65 to 6.95 kΩ

0°C (32°F)

4.40 to 5.35 kΩ

5°C (41°F)

3.40 to 4.15 kΩ

10°C (50°F)

2.70 to 3.25 kΩ

15°C (59°F)

2.14 to 2.58 kΩ

20°C (68°F)

1.71 to 2.05 kΩ

25°C (77°F)

1.38 to 1.64 kΩ

30°C (86°F)

1.11 to 1.32 kΩ

If the resistance is not as specified, replace the No. 1 cooler thermistor.

NOTICE:

  • Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
  • When measuring, the sensor temperature must be the same as the ambient temperature.

HINT:

As the temperature increases, the resistance decreases (see the graph).

    Components

    Installation

    See More:

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Intuitive Parking Assist System(for Gasoline Model): Calibration
    CALIBRATION NOTICE: When any of the following parts have been replaced, perform adjustment shown in the following table. If not, the intuitive parking assist system may not operate correctly. ADJUST INTUITVE PARKING ASSIST SYSTEM (a) The necessary procedures (adjustment, calibration, initialization ...

    Toyota Avalon (XX50) 2019-2022 Owners Manual

    Toyota Avalon (XX50) 2019-2022 Service & Repair Manual

    © 2025 Copyright www.tavalon.net