Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
Reclining Rear | Reclining switch signal (Rearward) |
ON or OFF | ON: Reclining switch (Rearward) on
OFF: Reclining switch (Rearward) off |
- |
Reclining Front |
Reclining switch signal (Forward) |
ON or OFF | ON: Reclining switch (Forward) on
OFF: Reclining switch (Forward) off |
- |
Front Vertical Down |
Front vertical switch signal (Downward) |
ON or OFF | ON: Front vertical switch (Downward) on
OFF: Front vertical switch (Downward) off |
- |
Front Vertical Up |
Front vertical switch signal (Upward) |
ON or OFF | ON: Front vertical switch (Upward) on
OFF: Front vertical switch (Upward) off |
- |
Lifter Switch Down |
Lifter switch signal (Downward) |
ON or OFF | ON: Lifter switch (Downward) on
OFF: Lifter switch (Downward) off |
- |
Lifter Switch Up |
Lifter switch signal (Upward) |
ON or OFF | ON: Lifter switch (Upward) on
OFF: Lifter switch (Upward) off |
- |
Slide Rear |
Slide switch signal (Rearward) |
ON or OFF | ON: Slide switch (Rearward) on
OFF: Slide switch (Rearward) off |
- |
Slide Front |
Slide switch signal (Forward) |
ON or OFF | ON: Slide switch (Forward) on
OFF: Slide switch (Forward) off |
- |
Seat Memory No1 |
Seat position memorized with M1 switch |
Mem or Not Mem | Mem: Memorized
Not Mem: Not memorized |
- |
Seat Memory No2 |
Seat position memorized with M2 switch |
Mem or Not Mem | Mem: Memorized
Not Mem: Not memorized |
- |
Seat Memory No3 |
Seat position memorized with M3 switch* |
Mem or Not Mem | Mem: Memorized
Not Mem: Not memorized |
Not applicable |
Ignition Switch | Communication state of power switch signal |
ON or OFF | ON: Power switch on (IG)
OFF: Power switch off or on (ACC) |
- |
Parking Brake SW |
Parking brake switch status |
ON or OFF | ON: Parking brake applied
OFF: Parking brake released |
- |
Vehicle Speed |
Vehicle speed data | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) |
Actual vehicle speed |
- |
Slide Position |
Seat sliding position |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Reclining Position |
Seat reclining position |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Front Vertical Position |
Seat front vertical position |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Lifter Position |
Seat lifter position |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Slide Pos Mem No1 |
Seat slide position memorized with M1 switch |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Reclining Pos Mem No1 |
Seat reclining position memorized with M1 switch |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Frnt Vrtcl Pos Mem No1 |
Front vertical position memorized with M1 switch |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Lifter Pos Mem No1 |
Lifter position memorized with M1 switch |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Slide Pos Mem No2 |
Seat slide position memorized with M2 switch |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Reclining Pos Mem No2 |
Seat reclining position memorized with M2 switch |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Frnt Vrtcl Pos Mem No2 |
Front vertical position memorized with M2 switch |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Lifter Pos Mem No2 |
Lifter position memorized with M2 switch |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Slide Pos Mem No3 |
Seat slide position memorized with M3 switch* |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
Not applicable |
Reclining Pos Mem No3 | Seat reclining position memorized with M3 switch* |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
Not applicable |
Frnt Vrtcl Pos Mem No3 |
Front vertical position memorized with M3 switch* |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
Not applicable |
Lifter Pos Mem No3 | Lifter position memorized with M3 switch* |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
Not applicable |
Lumbar Switch UP | Lumbar support adjuster switch signal (Upward) |
ON or OFF | ON: Lumbar support adjuster switch (Upward) on
OFF: Lumbar support adjuster switch (Upward) off |
- |
Lumbar Switch Down |
Lumbar support adjuster switch signal (Downward) |
ON or OFF | ON: Lumbar support adjuster switch (Downward) on
OFF: Lumbar support adjuster switch (Downward) off |
- |
Lumbar Switch Front |
Lumbar support adjuster switch signal (Forward) |
ON or OFF | ON: Lumbar support adjuster switch (Forward) on
OFF: Lumbar support adjuster switch (Forward) off |
- |
Lumbar Switch Rear |
Lumbar support adjuster switch signal (Rearward) |
ON or OFF | ON: Lumbar support adjuster switch (Rearward) on
OFF: Lumbar support adjuster switch (Rearward) off |
- |
Lifter Initialize Flag |
Seat lifter limit position memory |
ON or OFF | ON: Memorized
OFF: Not memorized | - |
Front Vertical Init Flag |
Seat front vertical limit position memory |
ON or OFF | ON: Memorized
OFF: Not memorized | - |
Reclining Position Init Flg |
Seat reclining limit position memory |
ON or OFF | ON: Memorized
OFF: Not memorized | - |
Slide Position Init Flag |
Seat slide limit position memory |
ON or OFF | ON: Memorized
OFF: Not memorized | - |
Slide Position Front Limit |
Seat slide limit position (front) |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Slide Position Rear Limit |
Seat slide limit position (rear) |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Reclining Position Front Limit |
Seat reclining limit position (front) |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Reclining Position Rear Limit |
Seat reclining limit position (rear) |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Front Vertical UP Limit |
Seat front vertical limit position (up) |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Front Vertical Down Limit |
Seat front vertical limit position (down) |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Lifter Position UP Limit |
Seat lifter limit position (up) |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Lifter Position Down Limit |
Seat lifter limit position (down) |
Min: 0, Max: 65535 | Within range from 0 to 65535 |
- |
Memory Button Buzzer Request |
Driver seat buzzer request display |
OFF, MOVE, REGISTRY, CANCEL, REG NG, REG WAIT |
OFF: Buzzer does not sound MOVE: Request to sound buzzer when starting memory replay
REGISTRY: Request to sound buzzer when starting memory registration
CANCEL: Request to sound buzzer when canceling memory call registration
REG NG: Request to sound buzzer when memory call registration not possible
REG WAIT: Request to sound buzzer when starting memory call cabin scan |
- |
Driver Seat Request Command |
Driver seat operation request received |
OFF, MEMORY, MEM MOV, MEM SOD, RET MOV, AWY MOV, AWY SOD, MEM AWY or MEM RET |
OFF: No instruction MEMORY: Request to memorize MEM MOV: Request to recall memory
MEM SOD: Request to replay RET MOV: Request to return AWY MOV: Request to move away
AWY SOD: Request to recall away position memory MEM AWY: Request to recall memorized position of seatback
MEM RET: Request to restore seatback to memorized position |
- |
Driver Seat POS REQ |
Seat memory switch operation value |
OFF, MEM1, MEM2, MEM3*, DRV1*, DRV2* or DRV3* |
OFF: No operation MEM1: M1 switch operation status MEM2: M2 switch operation status
MEM3: M3 switch operation status* DRV1: Other 1 operation status*
DRV2: Other 2 operation status* DRV3: Other 3 operation status* |
- |
Away Move Range Scale |
Seat travel distance for power easy access system |
NONE, SMALL, STANDRD or LONG |
NONE: Seat travel distance none SMALL: Seat travel distance short
STANDRD: Seat travel distance normal LONG: Seat travel distance long |
- |
Return Move |
Return function | NOT AVL or AVAIL |
NOT AVL: Not available AVAIL: Available |
- |
Return & Away Function |
Return & away function |
NOT AVL or AVAIL | NOT AVL: Not available
AVAIL: Available | - |
Driver Seat Buckle SW | Driver seat belt buckle switch |
ON or OFF | ON: Driver seat belt fastened
OFF: Driver seat belt unfastened |
- |
Return Position |
Return position | Min: 0, Max: 65535 |
Within range from 0 to 65535 |
- |
Shift SW Position |
Park state signal | Shift P or Shift Other |
Shift P: Shift lever in P Shift Other: Shift lever in a position other than P |
- |
ECU Voltage Value |
Voltage of position control ECU assembly |
0.95 to 20.84V | 11 to 14V |
- |
Battery Voltage Value |
Auxiliary battery voltage |
0.95 to 20.84V | 11 to 14V |
- |
Number of Trouble Codes |
Number of trouble codes |
Min.: 0 or Max.: 255 | Number of DTCs will be displayed |
- |