DESCRIPTION When the seat heater switch of the seat heater switch (radio and display receiver assembly) is operated, the air conditioning amplifier assembly receives a signal and operates the front seat heater. WIRING DIAGRAM CAUTION / NOTICE / HINT NOTICE:
PROCEDURE
(a) Clear the DTCs. Click here Body Electrical > Air Conditioner > Clear DTCs
(a) Check for DTCs. Click here Body Electrical > Air Conditioner > Trouble CodesOK: DTC B14B5 and B14C0 are not output.
(a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Air Conditioner / Active Test. (e) Perform the Active Test according to the display on the Techstream. Body Electrical > Air Conditioner > Active Test
OK: The seat heater operates normally.
(a) Remove the front seatback heater assembly RH. Click here (b) Inspect the front seatback heater assembly RH. Click here
(b) Measure the voltage and resistance according to the value(s) in the table below. Standard Voltage:
Standard Resistance:
(b) Disconnect the G37 air conditioning amplifier assembly connector. (c) Measure the voltage according to the value(s) in the table below. Standard Voltage:
(a) Reconnect the G37 air conditioning amplifier assembly connector. (b) Remove the air conditioning amplifier assembly with its connectors still connected. Click here (c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
(a) Disconnect the R6 front seat cushion heater assembly RH connector. (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:
|
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Sfi System: Control Module Internal Temperature Sensor "B" Circuit Short to Ground (P06AB11,P06AB15)
DESCRIPTION The ECM has a built-in internal temperature sensor which detects the internal temperature of the ECM. The resistance of the thermistor within the ECM internal temperature sensor changes according to the internal temperature of the ECM. The resistance of the thermistor increases as the EC ...