SYSTEM DESCRIPTION FUNCTION OF SRS CONNECTORS (a) Location of activation prevention mechanism ![]() (b) Function of activation prevention mechanism ![]() (1) This mechanism is designed to create a short circuit automatically between the positive (+) and negative (-) terminals of a squib power source connector when disconnected. (2) The short spring contained in the connector creates a closed circuit on the squib side (no potential difference can occur between both terminals), preventing accidental squib deployment when servicing. (c) Releasing of activation prevention mechanism (1) To release the activation prevention mechanism, insert a piece of paper with the same thickness as the male terminal (approximately 0.5 mm (0.0197 in.)) between the terminals and short spring to break the connection. (2) Refer to the following illustrations concerning connectors utilizing the activation prevention mechanism and its release method. CAUTION: Never release the activation prevention mechanism on the squib connector even when inspecting with the squib disconnected. NOTICE:
HINT: To prevent improper operation due to static electricity, etc., the connector of the airbag and pretensioner squib circuit has a short mechanism, and the squib terminal is shorted while the connector is disconnected. ![]() |
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Window Defogger System(for Gasoline Model): Terminals Of Ecu
TERMINALS OF ECU CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (a) Disconnect the G35 air conditioning amplifier assembly connector. (b) Measure the voltage and resistance according to the value(s) in the table below. HINT: Measure the values on the wire harness side with the connector disconnected. Ter ...