INSTALLATION PROCEDURE 1. INSTALL MOTOR CABLE CAUTION: Be sure to wear insulated gloves. (a) Using an insulated tool, install the motor cable to the hybrid vehicle transaxle assembly with the 6 bolts. Torque: 10 N·m {102 kgf·cm, 7 ft·lbf} NOTICE:
(b) Engage the 2 claws to install a new terminal cap to the hybrid vehicle transaxle assembly. NOTICE:
(c) Temporarily install the connector cover to the hybrid vehicle transaxle assembly with the 2 bolts. (d) Tighten the 2 bolts to install the connector cover. Torque: 10 N·m {102 kgf·cm, 7 ft·lbf} 2. INSTALL INVERTER WITH CONVERTER ASSEMBLY Click here |
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Coolant(for Inverter): Replacement
REPLACEMENT CAUTION / NOTICE / HINT CAUTION: To avoid the danger of being burned, do not remove the reserve tank cap or drain cock plug while the coolant (for inverter) is still hot. Pressurized, hot coolant (for inverter) and steam may be released and cause serious burns. *1 Reserve Tank Cap *2 Dra ...