DESCRIPTION The cause of this malfunction may be the generator high-voltage circuit. Check the generator internal resistance and the connection condition of the high-voltage line between the inverter and generator to check whether there is an open or short circuit. Related Parts Check
WIRING DIAGRAM CAUTION / NOTICE / HINT This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs. If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC. CAUTION:
NOTICE: After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work. Click here PROCEDURE
CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Remove the inverter cover from the inverter with converter assembly.
(d) Disconnect the motor cable from the inverter with converter assembly. (e) Check for arc marks at the terminals for the motor cable.
(f) Reconnect the motor cable. (g) Reinstall the inverter cover.
CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Remove the inverter cover from the inverter with converter assembly. (c) Disconnect the motor cable from the inverter with converter assembly.
(e) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below. NOTICE: Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected. Standard Resistance:
(f) Reconnect the motor cable. (g) Reinstall the inverter cover.
CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Remove the inverter with converter assembly.
(d) Disconnect the motor cable from the hybrid vehicle transaxle assembly. (e) Check for arc marks at the terminals for the generator cable.
(f) Reconnect the motor cable. (g) Reinstall the inverter with converter assembly.
CAUTION: Be sure to wear insulated gloves. (a) Check that the service plug grip is not installed. NOTICE: After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction. (b) Remove the inverter with converter assembly. (c) Remove the motor cable. (d) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below. NOTICE: Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
NOTICE: Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground. (e) Measure the resistance according to the value(s) in the table below. Standard Resistance:
(f) Reinstall the motor cable. (g) Reinstall the inverter with converter assembly.
|
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Audio And Visual System(for Hv Model): HD Radio Tuner Malfunction (B1551,B158D,B15A0,B15B0,B15B3,B15B7,B15BA,B15F9)
DESCRIPTION These DTCs are stored when a malfunction occurs in the radio and display receiver assembly. DTC No. Detection Item DTC Detection Condition Trouble Area B1551 HD Radio Tuner Malfunction When any of the following conditions is met: "HD Radio" tuner decorder malfunction "HD Radio" tuner aud ...