Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
Shutter Operation State |
Grille shutter operation state |
Standby, Open, Close or Prohibit |
Standby: Grille shutter in standby mode Open: Grille shutter opening
Close: Grille shutter closing Prohibit: Grille shutter operation disabled |
- |
Shutter Control State |
Grille shutter control state |
Normal or Maintenance | Normal: Normal mode
Maintenance: Maintenance mode |
- |
Close Motor Lock |
Motor lock detection state during grille shutter closing operation |
Undetected or Detected |
Undetected: Motor lock not detected during closing operation Detected: Motor lock detected during closing operation |
Displays statu of last closing operation |
Open Motor Lock | Motor lock detection state during grille shutter opening operation |
Undetected or Detected |
Undetected: Motor lock not detected during opening operation Detected: Motor lock detected during opening operation |
Displays statu of last opening operation |
+B Power Voltage | Auxiliary battery voltage |
Min.: 0.8 V, Max.: 20 V |
11 to 14 V | - |
Last Operation Direction |
Direction of last grille shutter operation |
Unknown, Open or Close |
Unknown: Direction of last grille shutter operation unknown Open: Last grille shutter operation was in opening direction
Close: Last grille shutter operation was in closing direction |
- |
Shutter Operation Initialization Result |
Result of grille shutter system initialization |
OK or NG | OK: Initialization was completed successfully
NG: Initialization was not completed successfully |
- |
Shutter Operation Half-Open Result for Active Test |
Result of Active Test Shutter Half-Open Operation |
OK or NG | OK: Operation is normal
NG: Operation is abnormal |
- |
Shutter Operation Lock Detection Result for Active Test |
Result of Active Test Shutter Closing Operation Lock Detection and Shutter Opening Operation Lock Detection |
Normal, Open Error or Close Error |
Normal: Normal lock detected Open Error: Lock detected in abnormal position while performing Active Test Shutter Opening Operation Lock Detection
Close Error: Lock detected in abnormal position while performing Active Test Shutter Closing Operation Lock Detection |
- |
Shutter Operation Fixed Length Result for Active Test |
Result of Active Test Shutter Closing Operation Fixed Length and Shutter Opening Operation Fixed Length |
Normal, Open Error or Close Error |
Normal: Normal operation length Open Error: Abnormal operation length while performing Active Test Shutter Opening Operation Fixed Length
Close Error: Abnormal operation length while performing Active Test Shutter Closing Operation Fixed Length |
- |
Shutter Operation Mode |
Grille shutter operation mode |
Normal Mode, Change Sleep Mode, Sleep Mode or Release Sleep Mode |
Normal Mode: Normal mode Change Sleep Mode: Winter control transition mode
Sleep Mode: Winter control mode Release Sleep Mode: Winter control cancel mode |
- |
Last Operation Pulse Value |
Number of pulses of last grille shutter operation |
0 to 65535 edge | Between 0 to 65535 edge |
- |
Current Position |
Current grille shutter position |
0 to 65535 edge | Between 0 to 65535 edge |
- |
Maximum Open Position |
Grille shutter open position |
0 to 65535 edge | Between 0 to 65535 edge |
- |
Maximum Close Position |
Grille shutter closed position |
0 to 65535 edge | Between 0 to 65535 edge |
- |
Shutter Initialization |
Grille shutter system initialization |
Incomplete or Complete |
Incomplete: Grille shutter system initialization has not been completed
Complete: Grille shutter system initialization has been completed |
- |
End Shaft SW |
End shaft switch state |
Unset, Fully Open Position, Fully Closed Position or Half Open Position |
Unset: Grille shutter position unknown Fully Open Position: Grille shutter in fully open position
Fully Closed Position: Grille shutter in fully closed position
Half Open Position: Grille shutter between fully open and fully closed position |
- |
Ambient Temperature |
Ambient Temperature | -78.75 to 78.125°C |
Actual ambient temperature displayed (in °C) |
- |
Regulator Pressure Sensor |
Refrigerant pressure |
0.0147 to 3.7450 MPa | Actual refrigerant pressure displayed (in MPa) |
- |
Engine Coolant Temperature |
Engine coolant temperature |
16 to 127°C | Actual engine coolant temperature displayed (in °C) |
- |
Code Clear Request Flag |
Reception condition of DTC clear request signal to the grille shutter ECU from the ECM |
0 or 1 | 0: Not receiving DTC clear request signal
1: Receiving DTC clear request signal |
- |
Driving Cycle Change Flag |
Reception condition of driving cycle transition signal from ECM* |
0 or 1 | 0: Not receiving driving cycle transition signal
1: Receiving driving cycle transition signal |
Not applicable |
IG SW | Power switch |
0 or 1 | 0: Power switch off or on (ACC)
1: Power switch on (IG) |
- |
HV Control Coolant Temperature |
Inverter coolant temperature |
16 to 127°C | Actual inverter coolant temperature displayed (in °C) |
- |
Shutter Open Request |
Reception condition of grille shutter open request signal from hybrid vehicle control ECU assembly |
0 or 1 | 0: Not receiving grille shutter open request signal
1: Receiving grille shutter open request signal |
- |
HV Control Coolant Temperature Error Flag |
Inverter coolant temperature sensor condition sent from hybrid vehicle control ECU assembly |
0 or 1 | 0: Inverter coolant temperature sensor is normal
1: Inverter coolant temperature sensor is malfunctioning |
- |
Vehicle Speed |
Vehicle speed | 0 to 255 km/h |
Actual vehicle speed displayed (in km/h) |
- |
Number of DTC |
Number of DTCs currently stored |
0 to 255 | Number of DTCs will be displayed |
- |