CAUTION / NOTICE / HINT HINT:
PROCEDURE
HINT:
(a) Measure the auxiliary battery voltage with the power switch off. Standard Voltage: 11 to 14 V If the voltage is below 11 V, recharge or replace the auxiliary battery before proceeding to the next step. (b) Check the fuses and relays. (c) Check the connector connections and terminals to make sure that there are no abnormalities such as loose connections, deformation, etc.
(a) Using the Techstream, check for CAN communication system DTCs. Click here
(a) Refer to Problem Symptoms Table. Click here
(a) Operation Check Click here (b) Terminals of ECU Click here (c) Data List / Active Test Click here (d) Inspection
|
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Wireless Charging System(for Hv Model): Precaution
PRECAUTION PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL NOTICE: When disconnecting the cable from the negative (-) auxiliary battery terminal, initialize the following systems after the cable is reconnected. System Name See Procedure Lane Departure Alert System (w/ Ste ...