DESCRIPTION If the power
switch is pressed with the electrical key transmitter sub-assembly in
the cabin, the certification ECU (smart key ECU assembly) receives a
signal and changes the power source mode. Related Data List and Active Test Items
Problem Symptom | Data List and Active Test |
Power source mode does not change to on (IG) but does change to on (ACC) | Power Source Control
- Power Supply Condition
- IG Relay Monitor (Inside)
- IG Relay Monitor (Outside)
- IG Circuit
| WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
- When using the Techstream with the power switch off, connect the
Techstream to the DLC3 and turn a courtesy light switch on and off at
intervals of 1.5 seconds or less until communication between the
Techstream and the vehicle begins. Then select the vehicle type under
manual mode and enter the following menus: Body Electrical / Smart Key.
While using the Techstream, periodically turn a courtesy light switch on
and off at intervals of 1.5 seconds or less to maintain communication
between the Techstream and the vehicle.
- The smart key system (for Start Function, HV Model) uses the LIN
communication system and CAN communication system. Inspect the
communication function by following How to Proceed with Troubleshooting.
Troubleshoot the smart key system (for Start Function, HV Model) after
confirming that the communication systems are functioning properly.
Click here
- Make sure that no DTCs are output. If any DTCs are output, proceed to Diagnostic Trouble Code Chart.
- If the smart key system (for Start Function, HV Model) has been disabled, enable the system before performing troubleshooting.
Click here
- Inspect the fuses of circuits related to this system before performing the following procedure.
- Before replacing the certification ECU (smart key ECU assembly), refer to Registration.
Click here
- After completing repairs, confirm that the problem does not recur.
- After performing repairs, confirm that no DTCs are output by performing "DTC Output Confirmation Operation."
PROCEDURE (a) Using the Techstream, check for certification ECU (smart key ECU assembly) DTCs. Body Electrical > Power Source Control > Trouble Codes Body Electrical > Smart Key > Trouble Codes
Result |
Proceed to | DTCs are not output |
A | Smart key system (for Start Function, HV Model) DTCs are output |
B |
B |
| GO TO DIAGNOSTIC TROUBLE CODE CHART |
A |
| |
2. |
CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) |
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection | Condition |
Specified Condition |
G40-17 (IG1D) - Body ground |
Power switch off → Power switch on (ACC) |
1 V or less → 9 V or higher | |
|
*a | Component with harness connected (Certification ECU (Smart Key ECU Assembly)) | | |
NG |
| REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) |
OK |
| |
3. |
CHECK
HARNESS AND CONNECTOR (CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) -
INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY, AUXILIARY BATTERY AND BODY
GROUND) | (a) Disconnect the G40 certification ECU (smart key ECU assembly) connector.
(b) Disconnect the 4A, 4D, 4L and 4K instrument panel junction block assembly connectors.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition |
Specified Condition |
G40-17 (IG1D) - 4A-17 |
Always | Below 1 Ω |
4D-3 - Body ground | Always |
Below 1 Ω |
G40-17 (IG1D) or 4A-17 - Other terminals and body ground |
Always | 10 kΩ or higher |
(d) Measure the voltage according to the value(s) in the table below. Standard Voltage:
Tester Connection | Condition |
Specified Condition |
4L-1 - Body ground | Power switch off |
11 to 14 V |
4K-1 - Body ground | Power switch off |
11 to 14 V |
NG |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
OK |
| |
4. |
CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (IG1-NO. 1, IG1-NO. 2, IG2-NO. 2 RELAY) |
(a) Remove the instrument panel junction block assembly. Click here
(b) Connect all of the instrument panel junction block assembly connectors.
(c) Connect the G40 certification ECU (smart key ECU assembly) connector.
(d) Measure the voltage according to the value(s) in the table below.
*a | Component with harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Standard Voltage:
Tester Connection | Condition |
Specified Condition |
4F-14 - Body ground | Power switch on (IG) |
11 to 14 V |
4F-2 - Body ground | Power switch on (IG) |
11 to 14 V |
4F-15 - Body ground | Power switch on (IG) |
11 to 14 V |
4F-13 - Body ground | Power switch on (IG) |
11 to 14 V |
NG |
| REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
OK |
| |
5. |
CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - IG2 NO. 1 RELAY) |
(a) Remove the IG2 NO. 1 relay from the No. 1 engine room relay block and No. 1 junction block assembly.
(b) Disconnect the 4F instrument panel junction block assembly connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition |
Specified Condition |
4F-13 - No. 1 engine room relay block and No. 1 junction block assembly IG2 NO. 1 relay terminal 1 |
Always | Below 1 Ω |
No. 1 engine room relay block and No. 1 junction block assembly IG2 NO. 1 relay terminal 2 - Body ground |
Always | Below 1 Ω |
4F-13
or No. 1 engine room relay block and No. 1 junction block assembly IG2
NO. 1 relay terminal 1 - Other terminals and body ground |
Always | 10 kΩ or higher |
NG |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
OK |
| |
6. |
INSPECT IG2 NO. 1 RELAY |
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition |
Specified Condition |
3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 |
10 kΩ or higher |
3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 |
Below 1 Ω | | |
OK |
| USE SIMULATION METHOD TO CHECK |
NG |
| REPLACE IG2 NO. 1 RELAY | |